Patients who most need imaging exams may lack the
mobility necessary to move to the X-ray room or to position
themselves properly for optimum imaging. This is where
Agfa HealthCare’s mobile DX-D 100 with wireless detector
comes into its own. Designed for bedside use, DX-D 100
can handle a broad range of general radiography X-ray
studies, even for the least mobile patients. The very short
exposure time means images are available immediately
and can be validated straight away after exposure. The
higher productivity and image quality translate into lower
cost per exam and higher diagnostic efciency.
What’s more, the higher image quality also means
potential dose reduction for patients and operators. With
superb handling capabilities, it reduces waiting times and
increases diagnostic condence. The wireless detector
enhances the high exibility, while improving infection
control. The DX-D 100 further answers the need for
constant enhancement of patient comfort and performance
of your radiology department.






















WITH ITS EXCELLENT IMAGE QUALITY
AND FLEXIBLE HANDLING, THE MOBILE
DX-D 100 WITH WIRELESS DETECTOR OFFERS
FAST IMAGING THAT CAN BE VALIDATED
IMMEDIATELY.


              






            







Agfa HealthCare is a global leader in the fast growing market of integrated IT and imaging systems, offering
healthcare facilities a seamless ow of information and a 360˚ view of patient care. The company has a unique,
holistic approach, enabling it to provide in-depth clinical know-how and fully integrated hospital-wide solutions.
These specialized solutions integrate IT and imaging systems for Radiology, Cardiology, Mammography and
Orthopaedics. Agfa HealthCare’s enterprise-wide IT platform integrates all administrative and clinical data
within a healthcare facility and is designed to match the unique needs of specic healthcare professionals.
www.agfahealthcare.com
Why Agfa HealthCare?
M O B I L E D R S O L U T I O N
DX-D 100 WITH
WIRELESS DETECTOR
X-RAY TUBES
Type E7865X
E7884X
Nominal voltage 150 kV 150 kV
Nominal focus spot value 0.3 mm/1 mm 0.6 mm/1.2 mm
Nominal power small focus 3.2 kW 20 kW
Nominal power large focus 36.5 kW 50 kW
Anode target angle 12° 12°
Anode diameter 74 mm 74 mm
Anode heat content 100 kJ (140 kHU) 210 kJ (300 kHU)
Anode rotation speed Minimum 3200 min-1 Minimum 3200 min-1
GENERATOR VERSIONS
Maximum power kW 20 kW 32 kW 40 kW 50 kW
Maximum mA
320 mA 500 mA 500 mA 500 mA
Minimal kVp
40 kVp 40 kVp 40 kVp 40 kVp
Maximum kVp
125 kVp 150 kVp 150 kVp 150 kVp
Power Output (@ 0.1 s)
320 mA @ 62 kVp 500 mA @ 64 kVp 500 mA @ 80 kVp 500 mA @ 100 kVp
250 mA @ 80 kVp 400 mA @ 80 kVp 400 mA @ 100 kVp 400 mA @ 125 kVp
200 mA @ 100 kVp 320 mA @100 kVp 320 mA @125 kVp 320 mA @ 150 kVp
160 mA @ 125 kVp 250 mA @128 kVp 250 mA @150 kVp
200 mA @150 kVp
Compatible X-ray Tubes
E7865X E7865X E7884X E7884X
E7884X
Page view 0
1 2 3 4 5 6

Summary of Contents

Page 1 - WIRELESS DETECTOR

 Patients who most need imaging exams may lack the mobility necessary to move to the X-ray room or to position themsel

Page 2 - SP ECIF ICATION S

  On the go: easy handling for radiology examsThe DX-D 100 with wireless detector has been designed to offer full mobility combined with excellent

Page 3

  On the go: easy handling for radiology examsThe DX-D 100 with wireless detector has been designed to offer full mobility combined with excellent

Page 4

2 3 4On the go: easy handling for radiology examsThe DX-D 100 with wireless detector has been designed to offer full mobility combined with excellent

Page 5

 Patients who most need imaging exams may lack the mobility necessary to move to the X-ray room or to position themsel

Page 6

 Patients who most need imaging exams may lack the mobility necessary to move to the X-ray room or to position themsel

Comments to this Manuals

No comments